{"id":5735,"date":"2018-05-16T16:08:31","date_gmt":"2018-05-16T07:08:31","guid":{"rendered":"https:\/\/www.toyo-const.co.jp\/en\/?page_id=5735"},"modified":"2018-05-16T17:53:32","modified_gmt":"2018-05-16T08:53:32","slug":"struct7","status":"publish","type":"page","link":"https:\/\/www.toyo-const.co.jp\/en\/technology\/construction\/struct7","title":{"rendered":"Base Isolation Construction Method: TOSI"},"content":{"rendered":"<style>\nul.tokucho li:before {\ndisplay: inline-block;\n    content: '';\n    width: 14px;\n    height: 11px;\n    margin-right: 5px;\n    margin-left: -19px;\n    background: url(http:\/\/www.toyo-const.co.jp\/wp\/wp-content\/themes\/toyo2\/images\/common\/icon_check.png) left center no-repeat;\n    background-size: 14px 11px;\n}\n<\/style>\n<div class=\"widebox clearfix\">\nIn the conventional earthquake-resistant buildings, the tremor of the earthquake is directly transmitted from the ground and the building shakes greatly. In a base-isolated building, the base isolation device absorbs the tremor of the earthquake, which makes it possible to slightly shake the building.<\/p>\n<p>Toyo Construction Seismic Isolation Construction Method (TOSI) received technical reviews on design method, construction method, durability and maintenance at the Japan Seismic Isolation Structure Research Committee (JSSI) of the Japan Construction Center, and high reliability was confirmed.<\/p>\n<div class=\"mainimg\" style=\"text-align: center;\">\n        <img decoding=\"async\" src=\"https:\/\/www.toyo-const.co.jp\/en\/wp\/wp-content\/uploads\/2018\/05\/tec20_1.png\" alt=\"\"><br \/>\n        <img decoding=\"async\" src=\"https:\/\/www.toyo-const.co.jp\/en\/wp\/wp-content\/uploads\/2018\/05\/tec20_2.png\" alt=\"\">\n      <\/div>\n<\/div>\n<div id=\"typeC\">\n<div class=\"tecFeatureBox\">\n<div class=\"tecFeatureMiddle\">\n<h3 style=\"margin-bottom: 21px;\">Features<\/h3>\n<ul class=\"tokucho\" style=\"border: solid 3px #0068b6; padding: 30px 20px; color: #0068b6;\">\n<li style=\"margin-left: 19px;\">&#8220;High damping laminated rubber and laminated rubber with lead are alternately overlapped with &#8220;steel plate (hard)&#8221; and &#8220;rubber (soft)&#8221;. The heavy building is supported by &#8220;hardness of steel sheet&#8221;, while horizontal tremor of earthquake is isolated from the building by the \u201csoftness of rubber&#8221;.<\/li>\n<li style=\"margin-left: 19px;\">The slow vibration of the laminated rubber will take time to return to the original position, and the damper is used for adjustment.<\/li>\n<li style=\"margin-left: 19px;\">We examine the effect of base isolation by observation.<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/div>\n<div class=\"widebox clearfix\">\n<div class=\"mainimg\" style=\"text-align: center;\">\n        <img decoding=\"async\" src=\"https:\/\/www.toyo-const.co.jp\/en\/wp\/wp-content\/uploads\/2018\/05\/tec21.png\" alt=\"\">\n      <\/div>\n<\/div>\n<div class=\"cf\" id=\"typeC\">\n<div style=\"clear:both;\">\n<div class=\"tecDataBox\"><!--\u8cc7\u6599\u30a8\u30ea\u30a2 --><\/p>\n<div class=\"tecDataMiddle clearfix\">\n<h3>Construction examples<\/h3>\n<ul>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff081998\uff09Sankutas-Yoyogi\uff08Tokyo Metropolitan\uff09<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff082013\uff09New governmental office of Kinokawa city\uff08Wakayama pref.\uff09<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff081999\uff09Gueru-Huchinobe\uff08Kanagawa pref.\uff09<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff082013\uff09Miyagi Distribution Center, Ricoh Logistics System Co., Ltd. (Miyagi pref.)<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff082008\uff09Espoir Ayase\uff08Tokyo Metropolitan\uff09<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff082016\uff09North Fire Station of Okayama city (Okayama pref.\uff09<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff082012\uff09Advanced Trauma, Emergency and Critical Care Center, Oita University\uff08Oita pref.\uff09<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff082017\uff09Iwate Hospital, National Hospital Organization\uff08Iwate pref.\uff09<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff082012\uff09Shinonome Residential Tower\uff08Tokyo metropolitan\uff09<\/li>\n<li style=\"display: inline-block; width: 49%;\">\u25cf\uff082019\uff09New governmental building\uff08Wakayama pref.\uff09<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>In the conventional earthquake-resistant buildings, the tremor of the earthquake is directly transmitted from the ground and the building shakes greatly. In a base-isolated building, the base isolation device absorbs the tremor of the earthquake, which makes it possible to slightly shake the building. Toyo Construction Seismic Isolation Construction Method (TOSI) received technical reviews on design method, construction method, durability and maintenance at the Japan Seismic Isolation Structure Research Committee (JSSI) of the Japan Construction Center, and high reliability was confirmed. Features &#8220;High damping laminated rubber and laminated rubber with lead are alternately overlapped with &#8220;steel plate (hard)&#8221; and &#8220;rubber (soft)&#8221;. The heavy building is supported by &#8220;hardness of steel [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":5704,"menu_order":54,"comment_status":"closed","ping_status":"closed","template":"page-construction.php","meta":{"footnotes":""},"class_list":["post-5735","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages\/5735","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/comments?post=5735"}],"version-history":[{"count":1,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages\/5735\/revisions"}],"predecessor-version":[{"id":5736,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages\/5735\/revisions\/5736"}],"up":[{"embeddable":true,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages\/5704"}],"wp:attachment":[{"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/media?parent=5735"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}