{"id":5737,"date":"2018-05-16T16:12:17","date_gmt":"2018-05-16T07:12:17","guid":{"rendered":"https:\/\/www.toyo-const.co.jp\/en\/?page_id=5737"},"modified":"2018-05-16T17:53:55","modified_gmt":"2018-05-16T08:53:55","slug":"struct8","status":"publish","type":"page","link":"https:\/\/www.toyo-const.co.jp\/en\/technology\/construction\/struct8","title":{"rendered":"Base Isolation Installation Without Leaving: \u201cRetrofit\u201d"},"content":{"rendered":"<style>\nul.tokucho li:before {\ndisplay: inline-block;\n    content: '';\n    width: 14px;\n    height: 11px;\n    margin-right: 5px;\n    margin-left: -19px;\n    background: url(http:\/\/www.toyo-const.co.jp\/wp\/wp-content\/themes\/toyo2\/images\/common\/icon_check.png) left center no-repeat;\n    background-size: 14px 11px;\n}\n<\/style>\n<div class=\"widebox clearfix\">\n<p>By adding new seismic isolation function to the existing foundation, this method can reinforce the earthquake resistance without adding seismic members to the upper structure while occupants are staying.<\/p>\n<div class=\"mainimg\" style=\"text-align: center;\">\n        <img decoding=\"async\" src=\"https:\/\/www.toyo-const.co.jp\/en\/wp\/wp-content\/uploads\/2018\/05\/tec22.png\" alt=\"\">\n      <\/div>\n<\/div>\n<div id=\"typeC\">\n<div class=\"tecFeatureBox\">\n<div class=\"tecFeatureMiddle\">\n<h3 style=\"margin-bottom: 21px;\">Features<\/h3>\n<ul class=\"tokucho\" style=\"border: solid 3px #0068b6; padding: 30px 20px; color: #0068b6;\">\n<li style=\"margin-left: 19px;\">It is a construction method that can seismically isolate existing buildings supported by piles. This method is suitable for buildings of historical value because it doesn\u2019t change the appearance of the building. It is also appropriate for buildings of which uses are difficult to be suspended such as public facilities and hospitals because the building can be retrofitted while in use.<\/li>\n<li style=\"margin-left: 19px;\">The clearance that can be excavated around the building (approximately 2 to 4 m depending on the condition) is necessary.<\/li>\n<li style=\"margin-left: 19px;\">It can be applied to buildings with a tower ratio of less than 3 (tower ratio = building height \/ building width) where no pulling force is generated in the seismic isolation device.<\/li>\n<li style=\"margin-left: 19px;\">We acquired the patent (Patent No. 2819008) as Toyo type retrofit (TOTRO) that retrofit of an existing building can be further made in a labor-saving way.<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/div>\n<div class=\"widebox clearfix\">\n<div class=\"mainimg\" style=\"text-align: center;\">\n        <img decoding=\"async\" src=\"https:\/\/www.toyo-const.co.jp\/en\/wp\/wp-content\/uploads\/2018\/05\/tec23.png\" alt=\"\">\n      <\/div>\n<\/div>\n<div class=\"cf\" id=\"typeC\">\n<div style=\"clear:both;\">\n<div class=\"tecDataBox\"><!--\u8cc7\u6599\u30a8\u30ea\u30a2 --><\/p>\n<div class=\"tecDataMiddle clearfix\">\n<h3>Construction examples<\/h3>\n<ul>\n<li style=\"display: inline-block; width: 49%;\">\u25cf Seismic repair of Central Government Building no.3<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>By adding new seismic isolation function to the existing foundation, this method can reinforce the earthquake resistance without adding seismic members to the upper structure while occupants are staying. Features It is a construction method that can seismically isolate existing buildings supported by piles. This method is suitable for buildings of historical value because it doesn\u2019t change the appearance of the building. It is also appropriate for buildings of which uses are difficult to be suspended such as public facilities and hospitals because the building can be retrofitted while in use. The clearance that can be excavated around the building (approximately 2 to 4 m depending on the condition) is [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":5704,"menu_order":43,"comment_status":"closed","ping_status":"closed","template":"page-construction.php","meta":{"footnotes":""},"class_list":["post-5737","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages\/5737","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/comments?post=5737"}],"version-history":[{"count":1,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages\/5737\/revisions"}],"predecessor-version":[{"id":5738,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages\/5737\/revisions\/5738"}],"up":[{"embeddable":true,"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/pages\/5704"}],"wp:attachment":[{"href":"https:\/\/www.toyo-const.co.jp\/en\/wp-json\/wp\/v2\/media?parent=5737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}